Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | LS162A |
Usage/Application | Industrial |
Size | 120mm x 75mm x 25mm |
Display | UV rejection meter,IR rejection meter,Visible light Transmittance Meter,Three functions in ONE de |
Battery Life | 4*AAA alkaline battery |
Features | VL 550nm,UV 365nm,IR 1400nm |
As an Authorized dealer we are engaged in providing the broad assortment optical instruments.
Transmission Meter is special for film, window tint, filmed glass and side windshield test, it’s a small size, portable product for transmission value measurement. It’s able to simultaneously measure and display Visible transmission values and UV, Infrared rejection values.
Directly display the rejection rate of UV and infrared. In this way, when the customers are testing the performance of a solar film or a filmed glass, they can directly know the UV and infrared rejection rate of their measured sample, and don’t need to calculate how much 100% minus the transmission.
Specification:
Fetures
Additional Information:
Product Details:
Brand | Elcometer |
Model Name/Number | Elcometer 480 Glossmeter |
Standards | AS/NZS 1580.602.2,ASTM C584,ASTM C523,ASTM D523,ASTM D1455,ASTM D2457,ASTM D4039,ASTM E430 |
Measurement Range 20 Deg | 0-2000 GU |
Measurement Range 60 Deg | 0-1000 GU |
Measurement Range 85 Deg | 0-160 GU |
Measurement geometries | 60 deg.,20 60 deg.,20 60 85 deg. |
Measurement units | GU,HU,% |
Gauge memory | 40,000 readings in up to 2,500 batches |
Can be used in accordance with:
AS/NZS 1580.602.2, ASTM C584, ASTM C523, ASTM D523, ASTM D1455, ASTM D2457, ASTM D4039, ASTM D4449, ASTM D5767, ASTM E430, ASTM E2387, BS 3900 D5, DIN 67530, ECCA T2, EN 12373-11, EN 13523-2, ISO 7668, ISO 2813, ISO 13803, ISO 17025, JIS K 5600-4-7, JIS Z 8741, TAPPI T 653 (20°)
A well-integrated service support is provided from service centre with team of trained customer support group headed by a Service Manager, who double up for technical & application support to our customers.
Additional Information:
Product Details:
Observer | CIE 10 |
Display Data | Colorimetric Value,Color Difference Value/Graph,PASS/FAIL Result,Color Offset |
Optional accessory | miniature thermal printer,powder test box |
Measuring apertures | Switchable 8mm and 4mm |
Double locating | illuminating locating and cross locating |
Light Source | LED Light |
Sensor | Silicon photodiode array |
Illuminating/Viewing Geometry: | 8°/ d |
Light Source: | LED Light |
Sensor: | silicon photodiode array |
Measuring aperture: | Φ8mmflat aperture; Φ4mmtip aperture |
Color Space | CI E L ABXYZLChCI E RGBCI E LUV |
Color Difference Formula: | ΔE* ab, ΔE( h) , ΔE* uv,ΔE* 94, ΔE*cmc ( 2: 1) , ΔE*cmc ( 1: 1) , ΔE* 00 |
Other Chromaticity Data: | WI ( E313CI E, AATCCHunt er )YI ( D1925313)Color Fastness, Staining Fastness, J PC79BFD( 1. 5: 1)FMCI I |
Observer: | CI E 10° |
Illuminant: | D65ACD50F2F6F7F8F10F11F12 |
Display Data: | Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, |
Measuring Time: | 0. 4s |
Repeatability: | ΔE* ab 0. 03 (Average of 30 measurements of standard white plate within 5s) |
Errors between each instrument: | within Delta E*ab 0.2 |
Dimension: | 205*67*80mm |
Weight: | 500g |
Battery: | rechargeable lithium-ion battery 3. 7V @ 3200mAh |
Lamp Life: | 5 years, more than 1.6 million measurements |
Screen: | TFT 2.8 inch16: 9 |
Interface: | USB/ RS- 232 |
Storage: | 100 Standards, 20000 Samples |
Operating Temperature: | 0~40 32~104°F |
Storage temperature: | -20~50 4~122°F |
PC software: | CQCS3 software |
Optional accessory: | miniature thermal printer, powder test box |
Product Details:
Wavelength Range | 400-700 nm |
Mobility | Portable |
Brand | 3nh |
Model No / Item Code | NS810 |
Photometric Range | 0-200% |
Detector | Silicon Photodiode |
Data Output Port | USB/RS-232 |
Display | TFT 3.5inch, Capacitive Touch Screen |
Integrating Sphere Size | 58mm |
Dimensions | 90*77*230mm |
Measuring Time | 1.2 s |
Measuring Aperture | 8 mm |
Data Storage | 1000 Standards, 15000 Samples |
Power | Li-ion battery. 2800 times within 8 hours |
Weight | 600g |
Operating Temperature | 0-40 degree C |
Instrument Geometry | d/8 |
Display data | Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offs |
Additional Information:
Product Details:
Type | Portable |
Wavelength Range | 400-700nm |
Light Source | Gas filled tungsten lamp |
Measuring Geometrics | d/8,DRS spectral engine,fixed aperture 8mm viewing / 12mm illumination |
Illuminant Types | C,D50,D65,D75,A,F2,F7,F11,F12 |
Standard Observers | 2 deg. and 10 deg. |
Memory | 1,024 standards with tolerances,2,000 samples |
Standard a | AS/NZS 1580.601.3,ASTM C 609,ASTM D 2244,ASTM E 1164,ASTM E 308,ASTM E 313,BS 8493 |
Standarad b | DIN 5033-2,DIN 5033-3,DIN 5033-4,DIN 5033-7,DIN 6174,EN 12373-12,EN 13523-15 |
Standarad c | ISO 7724-2,ISO 7724-3,JIS K 5600-4-5,JIS K 5600-4-6,NF T36-006,NF X08-012-1,NF X08-012-2 |
Key Features
Measuring Functions and Indices
The Elcometer SP60 Portable Spectrophotometer provides absolute and difference measurements for the following colourmetric systems. These values can be obtained from any of the nine illuminants with 2° or 10° observer angle: L*a*b*, DL*Da*Db*, L *C*h°, DL*DC*DH*, DE*ab, DECMC, DE CIE94 and XYZ. Whiteness and Yellowness per ASTM E 313-98.
Pass/Fail Mode
The portable spectrophotometer instrument stores up to 1024 standards with tolerances for easy pass/fail measurement. A red/green LED indicator and the LCD display provide visual confirmation of results. A tone also sounds to indicate a fail result and measurement completion.
Quick Colour Compare
A quick measurement can be taken to compare two colours. This allows the operator to take quality control readings in a time efficient manner without having to create tolerances or store data.
The Sphere
SP60’s diffusing sphere is made of Spectalon®, a durable, highly reflective material designed to perform in a rigorous production environment. The diffusing material prevents degradation due to the flaking and chipping of the sphere wall material.
Opacity, Colour Strength and Shade Sorting
The portable spectrophotometer instrument can measure opacity as well as three colour-strength options: chromatic, apparent and tri-stimulus calculations. The Elcometer SP60 Portable Sphere Spectrophotometer also performs 555 shade sorting. This is an important consideration in the colour quality control of manufactured products involving plastics, painted or textile materials.
Texture and Gloss influence
To determine the influence of the specular component, the SP60 Portable Sphere Spectrophotometer allows simultaneous measurement of both specular - included (colour) and specular-excluded (appearance).
Part Number | Description | |||
SP60 Portable Sphere Spectrophotometer 8mm Fixed Aperture | ||||
Measuring Geometrics | d/8°, DRS spectral engine, fixed aperture: 8mm viewing/12mm illumination | |||
Light Source | Gas filled tungsten lamp | |||
Illuminant Types | C, D50, D65, D75, A, F2, F7, F11, F12 | |||
Standard Observers | 2° and 10° | |||
Spectral Range | 400-700nm | |||
Memory | 1,024 standards with tolerances, 2,000 samples | |||
Measurement Range | 0 to 200% reflectance | |||
Measuring Time | Approximately 2 seconds | |||
|
Additional Information:
Product Details:
Mobility | Portable |
Minimum Volume | 1 ml |
Display | 3 Display Digit |
Brand | 3nh |
Detector | Silicon Photodiode |
Country of Origin | Made in India |
Illuminating/Viewing Geometry | 8/d |
Measuring Aperture | 8mm / 4mm |
Color Space | CIEL*a*b*C*h* CIEL*a*b* CIEXYZ CIERGB CIEL*u*v* CIEL*C*h Yellowness & Whiteness Color Fastness |
Data Interface | USB |
Extended Aperture (optional) | 8mm extended aperture,available for measuring concave surface |
Illuminating/Viewing Geometry |
8/d |
Measuring Aperture |
Φ8mm |
Detector |
Silicon photoelectric diode |
Color Space |
CIEL*a*b*C*h* CIEL*a*b* |
Color Difference Formula |
E*ab L*a*b E*C*h |
Light Source |
D65 |
Light Source Device |
LED blue light excitation |
Errors Between Each Equipment |
≤0.50ΔE*ab |
Storage |
100pcs standards 20000pcs samples |
Repeatability |
Standard deviation within ΔE*ab 0.08 Average of 30 measurements of standard white plate |
Weight |
500g |
Dimension |
205×70×100 mm |
Power source |
Rechargeable lithium-ion battery 3.7V@3200mAh |
Lamp Life |
3 years, more than 1 million measurements |
Charging Time |
2 hours (First time 8 hours--100% electricity) |
Measurement Times Before Recharging |
More than 3000 times |
Operating Temperature/Humidity Range |
-10~40???, relative humidity 0~85% with no condensation |
Data Interface |
USB |
Optional Accessory |
Miniature thermal printer, Powder Test Box |
Product Details:
Usage/Application | Double Measurement End Face: Large area measurement and small area measurement |
Light Source | D65 |
Viewing Geometry | 8/d |
Measuring Aperture | 4mm |
Detector | Silicon photoelectric diode |
Measurement End Face | Large stable end-face and small concave-convex end-face |
Color Space | CIEL*a*b*C*h* CIEL*a*b* CIEXYZ |
Illuminating / Viewing Geometry |
8/d |
Measuring Aperture |
Φ4mm |
Detector |
Silicon photoelectric diode |
Locating |
Illuminating Locating/Cross Locating |
Measurement End Face |
Large stable end-face and small concave-convex end-face |
Color Space |
CIEL*a*b*C*h* CIEL*a*b* CIEXYZ |
Color Difference Formula |
E*ab L*a*b* E*C*h* |
Light Source |
D65 |
Light Source Device |
LED blue light excitation |
Errors Between Each Equipment |
≤0.80ΔE*ab |
Storage |
100pcs standards 20000pcs samples |
Repeatability |
Standard deviation within ΔE*ab 0.08 Average of 30 measurements of standard white plate |
Language |
English/Chinese |
Weight |
450g |
Dimension |
205×67×80 mm |
Power source |
Rechargeable lithium-ion battery 3.7V@3200mAh |
Lamp Life |
5 years, more than 1.6 million measurements |
Charging Time |
8 hours--100% electricity |
PC Software |
CQCS3 Software |
Printer (optional) |
Miniature thermal printer |
Product Details:
Measurement modes | Gloss Haze Haze Log DOI Peak Reflectance Reflected Image Quality |
Power Supply | Rechargeable Battery Pack |
Recharge Time | USB 4.5 hours |
Dimensions | 65 x 140 x 50mm |
Weight | 790g |
Gauge memory | up to 999 readings and curves |
Data output | USB Bluetooth |
On screen statistics | maximum & minimum value |
Key features:
Accurate
Simple
Flexible
Durable
Efficient
Powerful
Product Features | |
Easy to use menu structure |
English, Spanish, French, Italian, German, Chinese |
Bright colour screen; with permanent back light |
Adjustable brightness, 6 button touch sensitive interface |
User definable measurement display |
|
Scratch & solvent resistant display |
|
Mains or USB power supply |
|
Calibration certificate |
|
Data output |
|
USB; to PC |
|
Bluetooth®*: to PC or Android™ mobile device# |
|
On screen statistics |
x, σ, maximum & minimum value |
ElcoMaster® software & USB cable |
|
Date and time stamp |
|
Gauge memory; number of readings |
up to 999 readings & curves |
Repeat measurement mode |
user definable: 2, 5 or 10 seconds |
Delete last reading |
|
Standard & fixed batch sizes |
|
Trend, gloss & image graphs |
|
Measurement modes
|
Gloss (GU): 20°, 60°, 85°; Haze (HU) & Haze Log (HU Log); Distinctiveness of Image (DOI); Peak Reflectance (Rspec); Reflected Image Quality (RIQ) & Goniophotometric Profile
|
Measurement Range
Gloss
20°: 0-2,000GU;
60°: 0-1,000GU;
85°: 0-150GU
Haze
0-2,000GU
DOI
0-100 DOI
RIQ
0-100 RIQAdditional Information:
Product Details:
Weight | 2.5 kg |
Standards | ASTM D523, ISO2813 |
Measurement Range | 60 Degree: 0 - 1000 GU |
Memory | 199 readings |
Power Supply | 110 - 120V AC or 220 - 240V AC |
Aperture | 4.5mm dia |
Spot | 2 x 2mm |
Dimensions | 160mm x 220mm x 100mm |
The Novo Curve Gloss Meter 8mm (0.01sq inch) measurement area is approximately 3% of the area usually required by standard glossmeters.
Features:
Product Details:
Model Name/Number | TS7700 |
Optical System | D / 8 geometric optical structure,conforming to CIE No.15,GB / T 3978,GB 2893,GB / T 18833,iso |
Display | Spectrogram/Values,Samples Chromaticity Values,Color Difference Values/Graph,PASS/FAIL Result,Co |
Type | Portable |
Wavelength Range | 400 ~ 700 nm nm |
Size | 129 X 76 X 217mm |
Features:
§ D / 8 geometric optical structure, conforming to CIE No.15, GB / T 3978, GB 2893, GB / T 18833, iso7724 / 1, ASTM e1164, din5033 teil7;
§ Adopt combined LED light source with high life and low power consumption, including UV / excluding UV;
§ Switch 8mm & 4mm aperture( the flat/ tip measuring aperture can be switched easily, which is suitable for more tested sample)
§ Dual optical path system, the optical resolution in the visible range is less than 10nm, which can measure the SCI and SCE spectrum of the sample at the same time;
§ Accurate spectrum and lab data, used for color matching and accurate color transmission;
§ High hardware configuration: 3.5-inch TFT true color screen, capacitive touch screen, 1000 line blazed grating, silicon photocell array detector with large photosensitive area, etc;
§ USB / Bluetooth dual communication mode, wider adaptability;
§ Super dirt resistant and stable standard white calibration board;
§ Large capacity storage space, which can store more than 30000 pieces of test data
§ 10.2/10 standard observer's angle, multiple light source modes, multiple surface color systems, meet various standards of chromaticity indicators, and the needs of various customers for color measurement;
§ Camera locating position and Stabilizer cross measurement position;
§ PC software has powerful function expansion;
Additional Information:
Product Details:
Testing range T | Transmittance 0-100 |
Haze degree | 0-30.00 |
Display | Average value of transmittance and Haze degree automatically. |
Operation | Transmittance degree and haze degree can be switched automatically; |
Solid standard sample | 50mm x 50mm |
Solid full-page proof | width: 380mm, thickness: 130mm |
Product Details:
Material | ABS |
Usage | Optical Densitometer |
Sample Volume | 1 |
Weight | 2.1kg |
Density Range | D=0.00 - 5.00 |
Measuring Error | 0.00 - 2.00 0.02D,2.00 - 4.50 0.05D,4.50 - 5.00 0.06D |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | Elcometer 407 |
Usage/Application | Industrial |
Measuring Geometry | 20, 60 and 85 degree reflective angles |
Brand | Elcometer |
Memory | 200 readings |
Power Source | 4 x LR6 (AA) |
Additional Information:
Product Details:
Power Supply | 1.5V alkaline Battery |
Measure range | 0~100 |
Measurement condition | 45/0 (45 exposure, 0 receive) |
Repeatability | 1.5% |
Feature
Specification :
The terms "contrast ratio", "opacity" and "hiding power" are used interchangeably throughout the coatings industry but on this page, in order to simplify matters, only the term opacity will be used. Opacity is defined as the ability of a coating to prevent the transmission of light. A practical example of this is the case where a yellowwall is painted using a red paint. The greater the opacity the red paint, the more efficient it will be at hiding the underlying yellow colour
Opacity is defined by how a wet film of the test coating is applied to a black and white patterned substrate. After the film has dried, a reflectance meter or a spectrophotometer is used to measure the amount of light reflected from the overcoated black areas of the substrate. This is then expressed as a percentage of the amount of light reflected from the overcoated white areas. This value is the opacity of the film.
A paint which is highly opaque will obscure the black and white areas to an equal extent. In this situation, equal amounts of light will be reflected from the overcoated black and white areas and consequently an opacity value of 100% will be obtained.
Glossmeter rapid LED technology accurately and repeatably measures up to 3 angles at the same time.
Standard Mode :
1+ reading per second, (70+ readings per minute);
< 0.3 seconds per angle
Auto Repeat Mode :
3 readings per second, (180 readings per minute);
~ 0.1 seconds per angle
Scan Mode :
10 readings per second, (600 readings per minute);
~ 0.03 seconds per angle
Fully customisable, scratch and solvent resistant colour LCD allows the user to display:
Color Matching Box is our updated version, and it can accommodate up to 5 light sources. The consistency of the light sources in all Tilo Colour Assessment Cabinets gives excellent viewing conditions for reliable colour critical decisions under consistent lighting.
Color Matching Box can be applied to the industries that need to perform color difference testing as follows: as the premiere designer and manufacturer of color matching instrument products for the Graphic arts, Photographic, Textile, Dyeing, Packaging, Printing, Leather, Inks, Knitwear, Plastic, Automotive and Ceramics industries.
Color Matching BoxFeatures:
1. Color Matching Box render color more accurately. With 5 different light sources(D65, TL84, CWF, F, UV), which can detect the metamerism.
2. Meets or exceeds major international standards for visual color evaluation including: ASTM D1729, ISO3664, DIN, ANSI and BSI.
3. Easy to operate by using individual switches for each light source.
4. Elapsed time meter for tracking optimal lamp replacement.
5. Automatically alternating among light sources.
6. No warm-up time or flickering which insures quick and reliable color judgment.
7. Economic power consumption and low heat generation for high light efficiency.
8. The dimension can be made by customized.
About Light Sources:
Light Source | Color Light Box Application | Color temperature(k) | Power(W) |
D65 : | International standard Artificial Daylight | 6500 | 18 |
TL84 : | Applied to stores in Europe, Japan and China | 4000 | 18 |
CWF : | (Cool White Fluorescent)American Standard | 4150 | 18 |
F : | "Sun-setting Light Yellow" incandescent light source(imitation of sunset) | 2700 | 40 |
UV : | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wavelength:365nm | 20 |
TL83 : | Applied to stores in Europe | 3000 | 18 |
Remarks: Optional tubes D50, D75, TL83, U30, U35, A
Product Details:
Accuracy | Better than +/-2 % (Colorless and transparent material) |
Resolution | 0.1% for measured value less than 10% and 1% for other ranges; |
VL Peak wavelength | 550 nm |
UV Peak wavelength | 365 nm |
IR Peak wavelength | 940 nm |
Test sample size | Less than 40*40mm |
As an Authorized dealer we are engaged in providing the broad assortment optical instruments.
Split transmission meter has three independent testing units to measure the transmittance value of ultraviolet light, infrared light, and visible light.
is able to simultaneously measure and display..
It is used for the transmittance testing of glass, plated film, organic materials, solar film and other translucent materials such as insulating glass, filmed glass, PMMA materials etc.
It consist of two parts: main part for measuring and displaying functions and the auxiliary part for light source and laser light for alignment.
Specifications :
ø Two-parts dual mode of the main and auxiliary part facilitates the transmittance measurement of the automobile front windshield glass and building glass.
ø The built-in lithium rechargeable battery is easy for use without replacing the battery;
ø Use the USB port of computer to charge the meter via the built-in charger;
ø The laser alignment function guarantees the accurate alignment of the main part with the auxiliary part in the process of measurement and ensures accurate measurement.
ø Three light Transmittance Meter in one device; result is the average of three values
ø Two laser for two part alignment, more accuracy.
Product Details:
Usage/Application | Laboratory |
Model Name/Number | LS117 |
Density Measuring range | 0.00 --- 6.00 OD |
Type | Transmission Densitometer |
Resolution | 0.0005% Transmission / 0.01 OD |
Density Accuracy | +/-0.02 (0 -2.00 OD), +/-2% (2.00-6.00 OD) |
Parameter:
1. Density Measuring range: 0.00 --- 6.00 OD
2. Dot Area Measuring range: 0 --- 100%
3. Resolution: 0.0005% Transmission / 0.01 OD
4. Density Accuracy: +/-0.02 (0 -2.00 OD)
+/-2% (2.00-6.00 OD)
5. Transmittance Accuracy: +/-1%(0% --- 50%)
+/-2%(50% --- 100%)
6. Aperture: 2mm
7. Light source: ANSI/ISO Visual
8. Power supply: 4*AAA alkaline battery
Features:
1. Completely self-contained operation. No independent power supply or light source required.
2. Ideal for all graphic arts film applications, from quality control to calibration.
3. Directly measures density, density difference and dot area.
4. Simple to operate and easy to use
5. Able to measure densities up to 6.0 OD
Product Details:
Wavelength Range | 400-700 nm |
Mobility | Portable |
Spectral Bandwidth | 1 nm |
Display | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Co |
Brand | 3nh |
Model No / Item Code | YS3060 |
Size | L*W*H = 184*77*105mm |
Country of Origin | Made in India |
Comply with CIE No.15???GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7, YS3060 grating spectrophotometer features UV, SCI/SCE, USB / bluetooth, 8mm / 4mm switch aperture, etc. It has high accuracy 0.03 based on white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.
YS3060 UV Grating Spectrophotometer
Full Illuminants + UV, 8mm&4mm Apertures, SCI&SCE, Bluetooth Comm, High Precision.
YS3020 Grating Spectrophotometer
Multi-illuminants, Customizable Aperture, SCI&SCE, Bluetooth Comm, High Precision.
YS3010 Grating Spectrophotometer
4 Illuminants, 8mm Aperture, SCI&SCE, Good Precision.
Features
Additional Information:
Product Details:
Range | 0~120 |
Resolution | 0.1 |
Illumination Condition | 45/0 |
Illuminant | LED 457nm |
Whiteness Formula | Blue Light Whiteness WB=R457 |
Measuring Aperture | 18x11 mm Rectangle |
Whiteness Meter is mainly used to directly measure the whiteness value of solid object or Powder with flat surface. It can be widely used in whiteness measurement of textile printing and dyeing, paint, chemical building materials, paper board, plastic products, white cement, ceramics, enamel, talc powder, starch, flour, salt, detergent, cosmetics and other substances.
* It consists of Light Source, Optical System, Detection System, Data Process and Display System. The whiteness Calculation Formula of the instrument is blue light whiteness R457.
* Use of high quality imported components, good reliability.
* The optical path design is reasonable, simple. Adopt filter system with correction, the whiteness can be reflected quantitatively.
* No preheating after starting, measurements can be taken after simple calibration, easy to operate.
* Pass strict inspection and testing, the instrument conforms to the JJG 512-2002 Whiteness Meter Verification Regulation. Also conforms to GB3978, GB3979, GB7973, GB7974, ISO2470, GB8904.2, QB1840, GB2913, GB13025.2, GB1543, ISO2471, GB10339, GB5950, GB12911, GB2409 and other standards.
* Able to memory 254 groups of measurement data.
* Use USB data out put and RS- 232 data out put to connect with PC.
* Provide Bluetooth data out put choice.
The light source of the instrument is long-life LED with 457nm, conforming to the light source requirement in the JJG 512-2002 National Metrological Whiteness Meter Verification Regulation. The measurement of the instrument adopts the principle of photoelectric effect. The diffuse reflectance Radiant Brightness Energy Value of the sample surface is receive by the optical cell. Then, the value is amplified by high-precision auto zeroing operation amplifier, inputted to the calibration circuit for energy calibration. Then, the whiteness value of the sample is directly shown on the digital display.
Range | 0~120 | |
Resolution | 0.1 | |
Illumination Condition | 45/0 | |
Illuminant | LED 457nm | |
Whiteness Formula | Blue Light Whiteness WB=R457 | |
Measuring Aperture | 18x11 mm Rectangle | |
Zero Drift | <<0.1 | |
Stability of Display | <<0.5 | |
Repeatability of Measurement | <<0.1 | |
Operating Gondition | Temperature | 0~40ºC |
Humidity | <85%RH | |
Power Supply | Lithium Battery | |
Size | Main Unit | 140x45x75 mm |
Probe | -------- | |
Weight | 305g(Including Batteries) |
Product Details:
Light source | 380nm-760nm full wavelength, in line with CIE photopic luminosity function |
Measurement accuracy | better than +- 1% (colorless and uniform transparent materials) |
Resolution | 0.001% (0% --- 10%); 0.01% (10% --- 100%) |
Weight | about 622 g (without battery) |
Test sample thickness | Less han 100mm |
Test sample diameter | Less than 10mm |
light transmittance meter can be used to test the light transmittance of glass products, solar films, laminated glass, coating materials, organic material panels and other materials. Suitable for display, production, quality inspection, inspection and other occasions.
Additional Information:
Product Details:
Wavelength | Infrared: 850 nm, Visible light: 380nm-760nm(white light), Green light: 530nm |
Transmission Accuracy | +-1% |
Transmission Resolution | 0.005% |
Density measuring range | 0.00 OD ---5.00 OD |
Density resolution | 0.01 for 0.00 - 3.00OD, 0.05 for 3.00 - 5.00 OD |
emperature range | -20 DegreeC --- +70 DegreeC |
Power supply | 220V AC/50Hz |
Communication | Dual RS485 |
Online Optical Density Monitor is a non-contact online thickness tester for coating aluminized film, use the principle of optical transmittance to monitor the process of vacuum coating machine and the production line of glass, has two kinds of methods to display: transmittance and optical density.
The material of transmittance (optical density) and a certain proportion relationship with material of coating thickness. So by monitoring materials of optical transmittance (optical density) to achieve the uniformity of monitoring materials, the purpose of the coating thickness. As long as it is light through the material, can be monitored by monitoring the light transmittance product quality. Such as winding vacuum coating, coating, glass/film production line and so on.
System is divided into 3 parts:
a) Detection systems : Includes the source, receiver, controller and aluminum bracket;
b) Human-computer interaction devices : 7 inch LCD MMI, display the transmittance and optical density data of every test points.
c) Computer real-time monitoring system(Optional) : Data record, analysis, reporting, and other functions.
Due to the measured sample of this customer is more special, the card slot of our conventional glass transmittance on-line monitoring device is 20mm wide, can not meet customer needs. So we customized a flexible program, the test points, controllers and human-machine display interface will be provided by our company to test , collect, output and display dates. As for the bracket part,it will be customized according to the customer’s requirements. For this situation, the users will take the installation problem into account because my company doesn’t provide the whole set of glass transmittance on-line monitoring device.
This instrument provides dual RS485 communication interface, the standard MODBUS communication protocol, convenient for communications among LC, single-chip computer, MMI, kingview and computer. Coating machine can read directly optical density data of the equipment to realize the automatic control (closed-loop control).
Parameter:
1. Wavelength: according to the customer‘s need to choose, there are following option
Infrared : 850nm(the default option, strong anti-interference ability),
Visible light : 380nm-760nm(white light),
Green light : 530nm
2. Accuracy : ±1%
3. Resolution : 0.005%
4. Density measuring range : 0.00 -5.00 OD
5. Density resolution : 0.01 for 0.00 - 3.00 OD,
0.05 for 3.00 - 5.00 OD
6. The maximum measured points : 36
7. Distance between adjacent probe head:≥70mm
8. Distance between the sending and receiving probe: 20mm
9. Temperature range:-20°C +70°C
10. Data refresh cycle:300ms
11. Size:100mm*230mm(W*H) Length according to customer requirements
12. The number of flange electrode:
6 (Not deserve a computer monitor)
9 (Deserve a computer monitor)
13. Power supply:220V AC/50Hz
14. Communication:dual RS485.
Product Details:
Material | Metal |
Type | Mirror Light |
Color | Black |
Arm Length | 29 - 87 cm |
Packaging Type | Blister |
Shape | Rectagle |
Mirror size | 4.2 x 6.5 cm |
Handle length | 29 - 87 cm |
Power | 2 nos x CR2032 batteries |
Product Details:
Light Source | Gas filled tungsten lamp |
Measuring Geometrics | d/8 fixed 8mm aperture Simultaneous SPIN / SPEX |
other | DRS spectral engine, |
Illuminant Types | A, C, D50, D55, D65, F2, F7, F11 & F12 |
Standard Observers | 2 deg and 10 deg |
Spectral Ranges | 400-700nm |
Memory | 1,000 standards with tolerances, 4,000 samples |
Key Features
Measuring Functions and Indices
6085 provides absolute and difference measurements for the following colourmetric systems. These values can be obtained from any of the nine illuminants with 2° or 10° observer angle: L*a*b*, DL*Da*Db*, L *C*h°, DL*DC*DH*, DE*ab, DECMC, DE CIE94 and XYZ. Whiteness and Yellowness per ASTM E 313-98.
Pass/Fail Mode
The instrument stores up to 1000 standards with tolerances for easy pass/fail measurement. A simplified green tick shown on screen shows a straight forward pass indication or a red cross to show a failed. Results are shown at a glance showing detailed colour comparison data for analyst.
Quick Colour Compare
A quick measurement can be taken to compare two colours. This allows the operator to take quality control readings in a time efficient manner without having to create tolerances or store data.
The Sphere
6085’s diffusing sphere is made of Spectalon®, a durable, highly reflective material designed to perform in a rigorous production environment. The diffusing material prevents degradation due to the flaking and chipping of the sphere wall material.
Opacity, Colour Strength and Shade Sorting
The instrument can measure opacity as well as three colour-strength options: chromatic, apparent and tri-stimulus calculations. The Elcometer 6085 also performs 555 shade sorting. This is an important consideration in the colour quality control of manufactured products involving plastics, painted or textile materials.
Texture and Gloss Influence
To determine the influence of the specular component, the 6085 allows simultaneous measurement of both specular - included (colour) and specular-excluded (appearance).
Part Number | Description | Certificate |
K6085M001 |
Elcometer 6085 Ci60 Portable Sphere Spectrophotometer |
• |
K6085M002 |
Elcometer 6085 Ci62 Portable Sphere Spectrophotometer |
• |
Measuring Geometrics |
d/8°, DRS spectral engine, fixed 8mm aperture Simultaneous SPIN / SPEX |
|
Light Source | Gas filled tungsten lamp | |
Illuminant Types |
A, C, D50, D55, D65, F2, F7, F11 & F12 |
|
Standard Observers | 2° and 10° | |
Spectral Range | 400-700nm | |
Memory |
1,000 standards with tolerances, 4,000 samples |
|
Measurement Range | 0 to 200% reflectance | |
Measuring Time | Approximately 2 seconds | |
Product Details:
Measurement range | 0-120 |
Illumination geometric conditions | 45/0 |
Peak wavelength | 457 nm |
Stability | 0.2 |
Repeatability | 0.3 |
Accuracy | 1.5 % |
Product Details:
Power Supply | one 1.5V alkaline battery or rechargeable |
Measuring Abgle | 45 / 0 deg |
CIE | CIE Illuminant C |
Measurement range | 0-99.9 % |
Resolution | 0.1 |
Accuracy | +-1 unit or 1% of full scale |
This meter is used to measure the opacity, or luminous reflectance, of a grey scale. Suitable for the evaluation of a coatings hiding power, or simple shade sorting tasks of metallized films, anodized aluminum or ceramics. It can calculate the contrast ratio (opacity) and store it. The operator can call up the data when required. It complies with ISO 2814, ISO 3906 , ISO 6504, BS 3900 and DIN 55984.
Main Technical Parameters:
Product Details:
Sampling rate | 5K/S |
Frequency range | 5-2000Hz |
Frequency resolution | 5Hz |
Accuracy | 5% |
Standard | IES/ASSIST/Energy star/VESA |
Flicker mode | Flicker percentage, Flicker index |
FFT mode | Flicker frequency-domain diagram |
Lightwave mode | Flicker time-domain diagram |
Spectrum | ||
Sensor | CMOS Linear Image Sensor | |
Wavelength Range | 380 to 780 nm | |
Wavelength Data Increment | 2 nm | |
Spectral Bandwidth | Approximately 15 nm (Half Bandwidth) | |
Wavelength Reproducibility | ± 1 nm *1 | |
Measurement Range | 70 to 70,000 lx | |
Illuminance Accuracy | Illuminant A @ 2,856 K at 20,000 lx*2 | ± 5% |
CCT Accuracy | ± 3.5% | |
CRI Accuracy @ Ra | ± 2.5% | |
Stray Light | -25 dB max. *3 | |
Integration Time Range | 6 to 1,200 ms | |
Digital Resolution | 16 bits | |
Flicker | ||
Measurement Range | 30 to 60,000 lx | |
Sampling Rate | 5k sample/sec | |
Frequency Range | 5 to 2,000 Hz | |
Frequency Resolution | 5 Hz | |
Flicker Accuracy | ± 5% | |
Feature | ||
Capture Function | One time | |
Operation Mode | Standalone Mode | |
Integration Mode | Auto | |
we are engaged in providing the broad assortment of "RAL Colour Charts". RAL colour 4-digit references have been an accepted format for colour definition for more than 70 years.
RAL Colour Charts are basic collection consists of more than 200 colors available either in the form of fan-deck, booklet or chart in a gloss or semi-matt finish & globally accepted format for colour definition for more than 70 years.
Product Details:
Minimum Order Quantity | 1 Number |
Display | 2.8" TFT LCD, 240x320 Pixel, 262K color |
Type | Chroma |
Test | CCT, CRI, Lux, Lambda P and iTime, Plus, Flicker mode, FFT mode and light-wave mode. |
Spectral Bandwidth | 15nm |
Wavelength range | 380-780nm |
Integration time range | 6-1000ms |
Illuminance accuracy | 5% |
Storage | MicroSD slot |
easuring mode | Basic mode: | CCT, CRI, LUX, LambdaP, iTime |
Spectrum mode: | Color spectrum diagram | |
Flicker mode: | Flicker percentage, Flicker index | |
FFT mode: | Flicker frequency-domain diagram | |
Lightwave mode | Flicker time-domain diagram | |
Flicker | Sampling rate | 5K/S |
Frequency range | 5-2000Hz | |
Frequency resolution | 5Hz | |
Accuracy | 5% | |
Standard | IES/ASSIST/Energy star/VESA | |
Spectrum | Spectral Bandwidth | 15nm |
Wavelength range | 380-780nm | |
Integration time range | 6-1000ms | |
Illuminance accuracy | 5% |
Product Details:
Card Material | Plastic |
Usage/Application | RAL Colors Are Used For Information Defining Standard Colors For Varnish,Powder Coating And Plastic |
Color | Multicolor |
Brand | RAL |
Size | 20 x 50 mm |
Packaging Size | 213 RAL Classic colors |
Certification | CIELab system |
Light Source | Color Light Box Application | Color temperature(k) | Power(W) |
D65 : | International standard Artificial Daylight | 6500 | 18 |
TL84 : | Applied to stores in Europe, Japan and China | 4000 | 18 |
CWF : | (Cool White Fluorescent)American Standard | 4150 | 18 |
F : | "Sun-setting Light Yellow" incandescent light source(imitation of sunset) | 2700 | 40 |
UV : | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wavelength:365nm | 20 |
Remarks: Optional tubes D50, D75, TL83, U30, U35, A
we are engaged in providing the broad assortment of "RAL Colour Charts".
RAL colour 4-digit references have been an accepted format for colour definition for more than 70 years. RAL Colour Charts are basic collection consists of more than 200 colors available either in the form of fan-deck, booklet or chart in a gloss or semi-matt finish & globally accepted format for colour definition for more than 70 years.
we are engaged in providing the broad assortment of "RAL Colour Charts". RAL colour 4-digit references have been an accepted format for colour definition for more than 70 years.
RAL Colour Charts are basic collection consists of more than 200 colors available either in the form of fan-deck, booklet or chart in a gloss or semi-matt finish & globally accepted format for colour definition for more than 70 years.
Product Details:
Brand | 3NH |
Provide Installation Service | Yes |
Training | Live Online, Documentation |
Indexes & Graphics | WI, YI, Opacity, Color strength |
classify all colors | Spectral or formulas files |
Characterization | fitting curves of K (light absorption) and S (light diffusion) versus concentration. |
Correction Module | Correction by reformulation., Correction by adding |
Formulation | Display the best regarding DE, price or metamerism |
Additional Information:
Product Details:
Purple light Peak wavelength: | 395nm |
Blue light Peak wavelength | 460nm |
Visible light Peak wavelength | 380-760nm full wavelength,line with CIE photopic luminosity function |
Accuracy | +-2% (Colorless and transparent material) |
Resolution | 0.1% |
Size of Testing sample | less than 3mm |
Power supply | 5V DC Adapter |
As a Authorized dealer we are engaged in providing wide gamut of optical instruments used in various applications.
It is able to simultaneously measure and display PL??? Purple Light???, BL(Blue light) and VL(Visible Light) transmission values. This meter is self-contained light sources and self-calibration. No adjustment is needed. The users only need plug the power supply, turn on the switch and put the sample in the testing position. The resulting performance data appear on the display.
Specification :
ø Size: 200mm*180mm*106mm (L*W*H???
ø Size of Testing sample: > ???3mm
ø Weigh: 1500g
ø Resolution: 0.1%
ø Accuracy: ±2%(Colorless and transparent material)
ø 6.Purple light Peak wavelength: 395nm
ø Blue light Peak wavelength: 460nm
ø Visible light Peak wavelength: 550nm
ø Power supply: 5V DC Adapter
Features:
§ PL transmission meter, BL transmission meter, Light Transmittance Meter, Three function in ONE device.
§ Self-calibration and auto-calibration, NO need any manual adjustments.
§ Simple operation, putting the testing sample in the testing position, PL, BL and VL transmission values of the sample will simultaneously display.